Usually encountered the short service life of Fluorine Lined Magnetic Force Pump, the reasons are nothing more than two points:
One, the product quality of the vertical pump used is not good;
One, the product quality of the vertical pump used is not good;
Precautions for Fluorine Lined Magnetic Force Pump:
1. When using the Fluorine Lined Magnetic Force Pump, please do not change the chemistry of the delivery arbitrarily. The mixing of different chemistry will produce various chemical changes, and even the chemical reaction will generate high heat and damage the pump body. Please consult the staff for questions about chemical coordination.
2. There are many chemical properties, which will cause great harm to the human body. Personnel should try to avoid dangerous areas.
3. Before starting the power supply, check the correct position of the pipeline and valve, then start the power supply, and check whether the liquid is normal at any time.
4. The transportation of dangerous liquids under incorrect operating conditions, such as: the inlet and outlet valves are not opened, the pump material selection is incorrect, the dry operation operation, and the pipeline material does not match, will cause great danger. Especially during dry operation, the liquid in the pump will produce high temperature and vaporization. Some chemicals contain hydrogen, which can cause gas explosion or hydrogen explosion. Special attention should be paid to the operation.
5. After starting the Fluorine Lined Magnetic Force Pump, confirm the outlet flow. If the outlet flow is too small, immediately turn off the pump and check whether the pipeline is blocked.
6. When using in a special environment, if explosion-proof or pressure-proof and explosion-proof motors are required, please discuss with our company’s technicians.
7. When using in an environment containing chemical gases, a motor with a special treatment with anti-corrosion paint must be selected.
8. Any misuse, such as overpressure, self-modifying parts, chemical incompatibility, or use of damaged parts, may cause dangerous situations. Please follow the warning.
9. The temperature resistance of various types of materials is as follows: FRPP: 0-75°C PVDF: -20-90°C CPVC: 0-75°C CFRPP: 0-75°C
10. Be familiar with the operation of the machine before studying the problem. Please study the manual, which contains sufficient instructions to confirm to understand the standard operating procedures.
11. When the pump delivers dangerous liquids or is located in a dangerous environment, please wear protective gloves and glasses.